4 How to Use

4-5. How to wire

RM-5000

- 24 -

Connection conditions
• Cable: 0.08 - 2.5 mm

2

• Bare wire length: 8 - 9 mm
• Connecting tools: Dedicated screwdrivers manufactured by WAGO and equivalent (edge width 3.5 x 0.5

mm or less)








































Compatible bar terminal
For a bar terminal, the following items are available.
• Bar terminal (ferrule): Model 216 Series (manufactured by WAGO)

• Crimping tool: Model VarioCrimp 4 (206-204) (manufactured by WAGO)








z

Dedicated products

210-120J: ..... Standard model
210-350/01:.. Short model
210-258J: ..... Angle model

• When using a general-purpose

screwdriver, use one with an edge width
from 2.5 mm to 3.5 mm. Do not use a
screwdriver that does not fit into the
screwdriver slot or cannot open the spring
properly.

CAUTION

The specified bare wire length must be observed when the wire insulation is peeled off.
Improper clamping of the wire due to a shorter bare wire length may cause defective electric
conduction or heating.
Catching the wire insulation due to a shorter bare wire length may cause defective electric
conduction or heating.
Exposing the wire due to a longer bare wire length may cause defective insulation or a short circuit.
Be careful not to break up the wire. If the wire is broken up when inserted to the terminal, this may
cause defective insulation or heating.

8 - 9 mm

CAUTION

A bar terminal of the specified model must be used. Using other bar terminals invalidates the
warranty of the performance.