4 How to Use

4-5. How to wire

- 25 -

RM-5000

<How to Connect to Terminal Plate>

When cables are connected to the terminal plate, use the dedicated screwdriver or a compatible flathead
screwdriver to do so as shown below.










„

Wiring: Perform wiring as shown in the figure below.









„

Removal: In the same way as for the wiring procedure, insert the screwdriver to remove the wire.


CAUTION

The right tools must be used. Only one wire can be connected to one wiring hole.
When the wire is inserted into the driver slot by mistake, it does not contact the conductive part. This
may cause defective electric conduction or heating.
When the wire is inserted under the spring by mistake, it does not contact the conductive part. This
may cause defective electric conduction or heating.

(4) Properly peel off a wire and

insert it into the wiring hole
(round hole).
The wire will go in smoothly
if you insert the wire along
the edge of the round hole.

(5) When the wire is inserted as

far as it will go, pull out the
screwdriver while holding
the wire.

(6) To check whether the wire is

connected securely, pull the wire
gently.
(Do not pull the wire strongly.)

(1) Insert the screwdriver at an

angle into the operating slot
(square hole).

(2) While standing the

screwdriver upright, insert it
all the way securely.

(3) If you have done the previous

steps properly, the screwdriver is
kept upright when you let it go.