Specifications for each model – RKI Instruments RM-5000 Series Indicator/Alarm Unit User Manual

Page 78

Advertising
background image

10 Product Specifications

10-1. List of specifications

RM-5000

- 78 -

<Specifications for Each Model>

Model

GP-5001

NC-5001

NC-5001W

Gas to be detected

Combustible gas

Applicable gas
detector head

Catalytic combustion
type detector head

New ceramic type detector head

Gas alarm type

Two-step alarm (H-HH)

Detector head signal

Sensor direct signal

Cable for gas
detector head

CVV, etc. (1.25 sq or 2.0 sq) - 4-core

Distance to gas
detector head

2 km or less for CVV - 2.0 sq

Functions

Alarm delay/Suppression/Zero follower/Peak hold/Calibration history/Alarm trend
history/Event history

Power consumption

Max. 7 W (including the gas detector head; Approx. 10 VA if a multi-unit case is
used)

Model

NP-5001

SP-5001

GH-5001

Gas to be detected

High concentration gas

Combustible/toxic gas

Applicable gas
detector head

Thermal conductivity
type detector head

Hot-wire semiconductor
type detector head

Semiconductor type
detector head

Gas alarm type

Two-step alarm (H-HH)

Detector head signal

Sensor direct signal

Cable for gas
detector head

Shielded cable of CVVS,
etc. (1.25 sq or 2.0 sq) -
4-core

Cable of CVV, etc.
(1.25 sq or 2.0 sq) - 4-core

Cable of CVVS, etc.
(1.25 sq or 2.0 sq) - 3-core

Distance to gas
detector head

2 km or less for CVVS - 2.0
sq

2 km or less for CVV - 2.0
sq

2 km or less for CVVS - 2.0
sq

Functions

Alarm delay/Suppression/Peak hold/Calibration history/Alarm trend history/Event
history

Power consumption

Max. 7 W (including the gas detector head; Approx. 10 VA if a multi-unit case is
used)

Advertising