Blade ICE RACKSWITCH G8124-E User Manual

Page 130

Advertising
background image

BLADEOS 6.5.2 Application Guide

130 Chapter 8: Spanning Tree Protocols

BMD00220, October 2010

1.

Configure port membership and define the STGs for VLAN 1. Enable tagging on uplink ports that
share VLANs. Port 19 and port 20 connect to the Enterprise Routing switches.

2.

Add server ports 1 and 2 to VLAN 1. Add uplink ports 19 and port 20 to VLAN 1.

3.

Configure MSTP: Spanning Tree mode, region name, and version.

4.

Configure port membership and define the STGs for VLAN 2. Add server ports 3, 4, and 5 to
VLAN 2. Add uplink ports 19 and 20 to VLAN 2. Assign VLAN 2 to STG 2.

Note –

Each STG is enabled by default.

RS G8124(config)# interface port 19

RS G8124(config-if)# tagging

RS G8124(config-if)# exit

RS G8124(config)# interface port 20

RS G8124(config-if)# tagging

RS G8124(config-if)# exit

RS G8124(config)# vlan 1

RS G8124(config-vlan)# enable

RS G8124(config-vlan)# member 1,2,19,20

RS G8124(config-vlan)# stg 1

RS G8124(config-vlan)# exit

RS G8124(config)# spanning-tree mstp name MyRegion

RS G8124(config)# spanning-tree mode mst

RS G8124(config)# spanning-tree mstp version 100

RS G8124(config)# vlan 2

RS G8124(config-vlan)# enable

RS G8124(config-vlan)# member 3,4,5,19,20

RS G8124(config-vlan)# stg 2

RS G8124(config-vlan)# exit

Advertising
This manual is related to the following products: