Using the switch data ports – Blade ICE RACKSWITCH G8124-E User Manual

Page 29

Advertising
background image

BLADEOS 6.5.2 Application Guide

BMD00220, October 2010

Chapter 1: Switch Administration 29

Using the Switch Data Ports

You also can configure in-band management through any of the switch data ports. To allow in-band
management, use the following procedure:

1.

Log on to the switch.

2.

Enter IP interface mode.

Note –

Interface 125 through 128 are reserved for out-of-band management interfaces (see

“Using

the Switch Management Ports” on page 27

).

3.

Configure the management IP interface/mask.

Using IPv4:

Using IPv6:

4.

Configure the VLAN, and enable the interface.

5.

Configure the default gateway.

If using IPv4:

If using IPv6:

RS G8124> enable

RS G8124# configure terminal

RS G8124(config)# interface ip

<IP interface number>

RS G8124(config-ip-if)# ip address

<management interface IPv4 address>

RS G8124(config-ip-if)# ip netmask

<IPv4 subnet mask>

RS G8124(config-ip-if)# ipv6 address

<management interface IPv6 address>

RS G8124(config-ip-if)# ipv6 prefixlen

<IPv6 prefix length>

RS G8124(config-ip-if)# vlan 1

RS G8124(config-ip-if)# enable

RS G8124(config-ip-if)# exit

RS G8124(config)# ip gateway

<gateway number>

address

<IPv4 address>

RS G8124(config)# ip gateway

<gateway number>

enable

RS G8124(config)# ip gateway6

<gateway number>

address

<IPv6 address>

RS G8124(config)# ip gateway6

<gateway number>

enable