BLADEOS 6.5.2 Application Guide

BMD00220, October 2010

Chapter 13: VMready 175

Pre-Provisioning VEs

VEs may be manually added to VM groups in advance of being detected on the switch ports. By
pre-provisioning the MAC address of VEs that are not yet active, the switch will be able to later
recognize the VE when it becomes active on a switch port, and immediately assign the proper VM
group properties without further configuration.

Undiscovered VEs are added to or removed from VM groups using the following configuration
commands:

For the pre-provisioning of undiscovered VEs, a MAC address is required. Other identifying
properties, such as IPv4 address or VM name permitted for known VEs, cannot be used for
pre-provisioning.

Note –

Because VM groups are isolated from vNIC groups (see

“vNIC Groups” on page 157

),

pre-provisioned VEs that appear on vNIC ports will not be added to the specified VM group upon
discovery.

RS G8124(config)# [no] virt vmgroup

<VM group number>

vm

<VE MAC address>