Blade ICE RACKSWITCH G8124-E User Manual

Page 45

Advertising
background image

BLADEOS 6.5.2 Application Guide

BMD00220, October 2010

Chapter 2: Initial Setup 45

3.

Configure Gigabit Ethernet port flow parameters.

The system prompts:

Enter

rx

to enable receive flow control,

tx

for transmit flow control,

both

to enable both, or

none

to turn flow control off for the port. To keep the current setting, press <Enter>.

4.

Configure Gigabit Ethernet port autonegotiation mode.

If you selected a port that has a Gigabit Ethernet connector, the system prompts:

Enter

on

to enable port autonegotiation,

off

to disable it, or press <Enter> to keep the current

setting.

5.

If configuring VLANs, enable or disable VLAN tagging for the port.

If you have selected to configure VLANs back in Part 1, the system prompts:

Enter

d

to disable VLAN tagging for the port or enter

e

to enable VLAN tagging for the port. To

keep the current setting, press <Enter>.

6.

The system prompts you to configure the next port:

When you are through configuring ports, press <Enter> without specifying any port. Otherwise,
repeat the steps in this section.

Gig Link Configuration:

Port Flow Control:

Current Port EXT1 flow control setting:

both

Enter new value ["rx"/"tx"/"both"/"none"]:

Port Auto Negotiation:

Current Port EXT1 autonegotiation:

on

Enter new value ["on"/"off"]:

Port VLAN tagging config (tagged port can be a member of multiple VLANs)

Current VLAN tag support:

disabled

Enter new VLAN tag support [d/e]:

Enter port (INT1-14, MGT1-2, EXT1-24):