Vlan configuration example – Blade ICE RACKSWITCH G8124-E User Manual

Page 97

Advertising
background image

BLADEOS 6.5.2 Application Guide

BMD00220, October 2010

Chapter 6: VLANs 97

VLAN Configuration Example

Use the following procedure to configure the example network shown in

Figure 6

.

1.

Enable VLAN tagging on server ports that support multiple VLANs.

2.

Enable tagging on uplink ports that support multiple VLANs.

3.

Configure the VLANs and their member ports.

By default, all ports are members of VLAN 1, so configure only those ports that belong to other
VLANs.

RS G8124(config)# interface port 5

RS G8124(config-if)# tagging

RS G8124(config-if)# exit

RS G8124(config)# interface port 19

RS G8124(config-if)# tagging

RS G8124(config-if)# exit

RS G8124(config)# interface port 20

RS G8124(config-if)# tagging

RS G8124(config-if)# exit

RS G8124(config)# vlan 2

RS G8124(config-vlan)# enable

RS G8124(config-vlan)# member 3

RS G8124(config-vlan)# member 5

RS G8124(config-vlan)# member 19

RS G8124(config-vlan)# member 20

RS G8124(config-vlan)# exit

RS G8124(config)# vlan 3

RS G8124(config-vlan)# enable

RS G8124(config-vlan)# member 4,19,20

RS G8124(config-vlan)# exit