Ethernet-to-DeviceNet Linking Device 15
Rockwell Automation Publication 1788-IN055C-EN-P - September 2011
The following figure shows a flowchart describing how the IP configuration is
determined when the linking device is powered up.
TIP
You can enable these values using the linking device’s IP Configuration web
page. Refer to
Setting the IP Address Using By Using the Web Page on
page 16
.
Valid
Configuration
in Flash Memory?
DHCP
Config
Received?
Valid
Configuration
File?
DIP Switch = 0
DHCP
Enabled?
IP = 192 168.1.n
Sub = 255.255.255.0
No Gateway
Remain offline
Use Valid (stored)
IP address
Request config
from DHCP/
BOOTP Server.
Timeout 30 secs
Start
Stop
No
Yes
No
No
No
No
Use received
configuration
Yes
Yes
Yes
Yes
31445-M