Bendix Commercial Vehicle Systems SMARTIRE TPMS OPERATORS MANUAL User Manual

Page 32

Advertising
background image

32



5.6.2 Changing the Alert Thresholds

The “Vehicle Parameters” (vehicle params) function is used to adjust the default thresholds for
the pressure deviation, critical low pressure and high temperature alerts. The acronyms for each
alert along with the instructions for alert threshold customization are outlined below:

 Pressure Deviation Alert = FAL: First Alert Level

 Critical Low Pressure Alert = SAL: Second Alert Level

 High Temperature Alert = Over Temp


Follow the instructions below to customize the thresholds for each alert:

1. Enter the Setup Mode using the steps outlined in section 5.6.

2. When in the Setup Mode, press the left button until “Vehicle Params” is highlighted. Then

press the right button to select the function.

3. The alert thresholds for each alert will be displayed. Press the left button to highlight an

alert and the right button to select it for customization.

4. Press the left button to increase the number or the right button to decrease the number

until the desired value is shown. Hold down either button to quickly increase or decrease
the number. When the desired value is displayed, press the center button to save the
value.

5. Repeat steps 3 and 4 to continue customizing the alert thresholds until all values are

programmed correctly.

6. To save the changes and exit the “Vehicle Params” function, press the center button

once. Press the center button again to exit Setup Mode.


NOTE: The High Temperature Alert setting applies to all axle locations.

5.6.3 Changing the Cold Inflation Pressure (CIP) Value for Each Axle

The “Axle Parameters” (axle params) function is used to adjust the default cold inflation pressure
setting for each axle on the vehicle. Follow the instructions below to modify the CIP values for
each axle:

1. Enter the Setup Mode using the steps outlined in section 5.6.

Advertising