Doppler velocity subsystem – ADS Environmental Services Model 4000 530017 A0 User Manual

Page 104

Advertising
background image

5-18

ADS Model 4000 Manual

Problem

Ultrasonic depth sensor reports two abnormal
temperatures.

Possible

Causes

Ultrasonic depth sensor connection to monitor may be
loose.

Both temperature sensors may be faulty.

Ultrasonic depth sensor may be faulty.

Possible

Solutions

Secure ultrasonic depth sensor connection to monitor (if
necessary).

Replace the ultrasonic depth sensor.

Replace the depth board.

Doppler Velocity Subsystem

The following tables contain general troubleshooting techniques for
the Doppler velocity subsystem.

Note: Contact a trained ADS technician for further
diagnosis prior to replacing a sensor.

Advertising