ADS Environmental Services Model 4000 530017 A0 User Manual

Page 81

Advertising
background image

4-12

ADS Model 4000 Manual

Lightning protection module wiring diagram

Note: Remember, the wire colors referenced in this
manual are based on the telephone cable ADS
recommends for these applications. However, the wires
inside some telephone cables may vary in color and
number. Therefore, when the actual wire colors and
number differ from those designated in this manual,
connect the available wiring in reference to ground, ring,
and tip.

4. Run the two wires (secured to the posts on the left) down and

out through the grommet in the bottom of the module.

5. Place a washer onto each post, and replace the card.

6. Securely tighten a washer and nut onto each post over the card.

7. Make sure the ground wire (included with the lightning

protection module) is secured at the designated location on the
front left side of the card, and run the wire down through the
bottom grommet of the module.

8. Close and secure the front cover of the module.

9. Cut ½ inch (13 mm) of insulation from the loose end of the

black ground wire running from the lightning protection
module.

Advertising