Securing the sensor cables, Securing the cables to the ring (or band) – ADS Environmental Services Model 4000 530017 A0 User Manual

Page 65

Advertising
background image

3-42

ADS Model 4000 Manual

Securing the Sensor Cables

The following sections address securing the sensor cables to the
ring (or band), pipe, and manhole.

Securing the Cables to the Ring (or Band)

Securing the Doppler velocity sensor and pressure depth sensor
cables to the ring (or band, when applicable) helps prevent debris
from collecting between the cable and the ring or catching on the
loose cable. It also prevents the loose cables from disrupting the
flow.

Secure the Doppler velocity and pressure depth sensor cables in the
following way:

1. Starting at the appropriate sensor location, begin securing the

sensor cable with 4-inch (10-cm) x 0.08-inch (2-mm) cable ties
through the pre-drilled holes along the downstream trailing
edge of the ring up the side of the ring. Run the cable up the
side of the ring opposite the spreader mechanism (the left side
of the ring when facing the downstream edge of the ring).

Note: When securing both a pressure depth sensor and a
Doppler velocity sensor cable to the ring, place the
velocity cable on top of the pressure cable and secure both
together.

Sensor cabling