A-6

ADS Model 4000 Manual

Lightning Protection

The following table contains the specifications for the lightning
protection module and board.

Lightning

Protection

Module

(Service

Location)

Housing: Gray PVC

Dimensions: 4.13 inches (10.5 cm) high x 3.25
inches (8.3 cm) wide x 1.88 inches (4.8 cm) deep

Polyswitch: 600-volt 150-milliamps over-current
protector

Varistor: 240-volt over-voltage protector

Sidactor: 280-volt over-voltage protector

Ground Wire: 12 AWG black stranded

Service Wire: 22 AWG 4-conductor gray unshielded

Lightning

Protection

Board

(Monitor

Chassis)

Varistor: 240-volt over-voltage protector

Sidactor: 280-volt over-voltage protector

PTC Thermistor: 265-volt 300-milliamps over-current
protector

Maximum Surge Current: 7 kA (8 x 20 uS)

Maximum Transient Voltage: 20 kV (1.2 x 50 uS)

Maximum Clamping Voltage: 100 volts @3kA

Maximum Line Capacitance: 1600 pF

DC Operating Current: 300mA