1. Carefully strip about 3 inches of the external insulation from

each end of the telephone cable.

Stripping the external insulation from the telephone cable

2. Remove the internal braiding, and separate the four insulated

wires.

Separating the insulated wires

3. Cut off both the black and white wires down to the level of the

external insulation. These wires will not be used in this
application.

Note: The wire colors referenced in this manual are
based on the telephone cable recommended for use in
these applications. However, the wires inside some
telephone cables may vary in color and number.
Therefore, when the actual wire colors and number differ
from those designated in this manual, connect the
available wiring in reference to ground, ring, and tip.

4. Strip ½ inch (13 mm) of insulation from the remaining wires.