3-44

ADS Model 4000 Manual

Drive the plastic anchor into the pipe with a hammer until

flush and secure.

Run the cable tie through the loop in the plastic anchor

and around the cables.

Tighten the cable tie around the cables, and cut off the

excess cable tie material.

Warning: Overtightening the cable ties may damage the
sensor cables.

2. Secure the cables with a cable tie and plastic anchor every 18

to 24 inches (46 to 61 cm) along the pipe crown (when
necessary) from the ring to the manhole.

3. Secure the cables every 18 to 24 inches (46 to 61 cm) up the

side of the manhole to the monitor location. Loose cables
could present a manhole safety hazard or increase the potential
for sensor or monitor damage to occur.

Securing the sensors cables along the pipe and into the manhole