3 – Wiring Guidelines

Review this section to find instructions for wiring your BaseStation 3200 irrigation controller and

for connecting the standard and optional devices.

Conventional Irrigation Wiring Installation

BaseStation 3200R controllers and Baseline 5200R Series Powered biCoders connect directly to

conventional 24 VAC irrigation wiring, with one wire for each valve plus a common wire.

Additionally, these devices are capable of communicating to soil moisture sensors over specific

terminals that are enabled to search for and communicate with Baseline biSensors.

Conventional Wiring Modules

You can equip each 3200R controller with 12, 24, 36, or 48

zones, depending on the cabinet.

One 12 or 24 zone connection module fits in a C-series

cabinet. An X, XS, or P cabinet accommodates two 12 or 24

zone connection modules.

The terminal designations for each 12 or 24 zone

connection module are shown in the diagram on the right,

and include:

Rain Sensor Port (Normally Closed)

Note: When you connect a rain click device directly

to this port, the device will function globally without

any programming. When the contacts on the device

open, all watering will be set to Done and no

watering will start until the next start time after the

contacts have closed.

Two-wire Port (Red and Black)

Valve Common (x2)

Master Valve/Pump Start terminals (2, designated

VE1 and VE2) – you can re-address these terminals to

control conventional zones if desired

Sensor-over-valve-wire Ports (x2 for 12 zone, x4 for

24 zone) each with a status LED

Standard valve wire ports (x10 for 12 zone, x20 for 24

zone)