BaseStation 3200 Advanced Irrigation Controller Manual

Two-Wire Installation

All BaseStation 3200 and 3200R controllers are equipped with a full-function two-wire port capable

of connecting to valve biCoders, powered retrofit biCoders, biSensors, flow meters, and other

devices. Because Baseline’s biLine protocol provides full bidirectional communications, you can

connect all your irrigation accessories to the same two-wire path – saving time and money

compared to conventional wiring.

Two-Wire Serial Numbers

Each Baseline two-wire device has a unique serial number used to identify it. Serial numbers are

labeled on all Baseline devices. For devices such as two or four zone biCoders, each output for the

biCoder has a unique serial number, even if it only has one serial number listed on its label.

Serial Numbers for Four-zone biCoder

Two-Wire Connections and Layout

Baseline uses a proprietary digital protocol to communicate over two-wire. For the complete and

up-to-date two-wire specification, please refer to the Resource Library on the Baseline web site.

Wire Connections

Install all wire connections in compliance with the connector manufacturer’s instructions, and

make sure that the connections are fully waterproof.

Note: Use a 3M™ Direct Bury Splice Kit DBR/Y connector.

WARNING!

Do not connect the two-wire and valve common terminals together because this will

damage your BaseStation.

Baseline recommends that you allow 24 to 36 inches of strain relief at each wire connection to

make valve box installation and troubleshooting easier and to prevent thermal expansion from

pulling connections apart on long wire runs.