BaseStation 3200 Advanced Irrigation Controller Manual

Understanding the Ethernet Settings

When your controller is connected to a network with a supported communication module, the

system automatically assigns the networking addresses that enable the connection. You might

need to refer to this information in order to complete your connection or to troubleshoot it.

1. Connect and configure the communication module. Check the status lights and indicators on

your communication equipment to ensure that it is powered up and appears to be sending

and receiving data.

2. Turn the dial to the Network position.

3. Press the Next button to highlight the Ethernet

Setup option, and then press Enter. The Setup

Ethernet screen displays the following

information:

DHCP (Dynamic Host Configuration

Protocol) – The default network

configuration for the BaseStation 3200.

This protocol allows your controller to

automatically obtain an IP address which enables the connection to the Internet. Every

time you restart your controller, it retrieves a new IP address.

Static IP – An IP address that is permanently assigned

IP Addr – An Internet Protocol address (IP address) is a number assigned to a device

(such as the controller) that is connected to a computer network and uses the Internet

Protocol to communicate on the network.

Subnet Mask – The subnet mask is used with an IP address to indicate what network

traffic should be permitted or denied.

Default Gateway – An IP address that enables the network traffic from your controller

to pass through to a larger network

Preferred DNS Server 1 – A naming system (Domain Name System) for devices, such as

your controller, that are connected to the Internet

Preferred DNS Server 2 – An additional domain name that is assigned to your controller

Physical (MAC) Address – The Media Access Control address (MAC address) is a unique

identifier for your controller’s network connection

Enabling a Cell Modem Connection

If your BaseStation 3200 is running firmware version 12.4 or higher and you have a cell

modem installed and connected to the controller, the AT&T Cellular Modem Setup option on

the Advanced menu shows the status of the connection.

Refer to the Baseline Cell Modem Installation and User Guide.