BaseStation 3200 Advanced Irrigation Controller Manual

Searching For and Assigning Pump Start Devices and Master Valves

The BaseStation 3200 supports up to 8 normally open and/or normally closed master valves and/or

pump starts for the entire system. Valve decoders are assigned to Pump/MV numbers, and

flow+NOMV are assigned to MVs.

The following Pump/MV types are supported:

Normally Closed – uses a traditional valve decoder and is assigned to a POC

Normally Open – uses a traditional valve decoder, or is part of a Flow+NOMV decoder and is

assigned to a POC

Main pump – uses a traditional valve decoder (or a pump relay decoder) and is assigned to a

POC

Booster pump – uses a traditional valve decoder (or a pump relay decoder) and is assigned to

the list of programs

1. Turn the dial to the Water Sources position.

2. The Assign Decoders to Pumps/MVs option

should be highlighted in the box on the left. If

it is not highlighted, press the Next button to

highlight the option.

3. Press the Enter button. The Assign Pump/MV

screen displays.

4. The Search option should be highlighted in

the box on the left. If it is not highlighted,

press the + or button to highlight Search.

5. Press the Enter button. The system lists the serial numbers of all pump/MV devices that it

finds.

6. Press the + or button to highlight the serial number of the pump/MV device that you want

to assign, and then press the Enter button. The serial number moves from the list on the left

to an MV address row on the right.

7. When you have finished making changes, turn the dial to the RUN position.