Setting up a water source – Baseline Systems BaseStation 3200 V12 User Manual

Page 70

Advertising
background image

BaseStation 3200 Advanced Irrigation Controller Manual

Setting Up a Water Source

The BaseStation 3200 supports 8 points of connection (POCs). You can set limits and budgets for

each POC.

You can set the following values for each flow device on the Setup POC screen:

Note: The step-by-step procedure for setting up the water source is on page 64.

Design Flow – In this field, you can enter the specified gallons per minute (GPM) for the point

of connection (POC) that supplies water through the flow device to the rest of the irrigation

system. The BaseStation 3200 uses this value to manage the number of concurrent zones so

that the water source is used as efficiently as possible. If you set this value to zero, you cannot

use this GPM amount to control zone concurrency.

High Flow Limit – The system uses the GPM value in this field as a critical limit. When this

value is greater than zero, the system compares the limit against the measured reading from

the flow device every minute. If the flow rate reading exceeds the limit for three or four

minutes in a row, the system generates an alert.

If you set the Shut Down field to Y (yes), then programs using this POC will be stopped and

corresponding master valves (MVs) will be shut off when the flow rate exceeds the limit.

If the flow device is a Flow+NOMV type, the flow limit is programmed into the flow device.

The system monitors the high flow limit and the NOMV shuts off when the flow limit is

exceeded. When a flow device is connected to external power, the NOMV will shut off even

when the controller off or powered down.

Unscheduled Flow Limit – When this limit is set to greater than zero, the system monitors the

flow 24x7 for any flow that does not correspond to running programs.

When you have a NOMV, you can set this limit to allow some flow that is off schedule, such as

from manual taps or hose bibs.

If the flow exceeds the limit for several minutes, the system generates an alert. If you set the

Shut Down field to Y (yes), then the associated MVs will turn off.

Monthly Budget – When the value in this field is greater than zero, the system monitors the

total water used during a single month.

If the monthly water used exceeds this number, an alert is generated. If you set the Shut

Down field to Y (yes), then the associated MVs shut off and water is stopped until the first of

the next month.

Page 64

Advertising