Carlo Gavazzi WM5-96 User Manual

Page 16

Advertising
background image

14

Programming WM5 96

This function allows the user to select the calculation method of the
DMD/AVG value of the selected variable. To access these functions
select DMD/AVG CALCUL. from the main menu by means of the “

” keys and confirm the selection with “S”

(1)

.

TYPE

(2)

: select the type of calculation mode to be used for the

DMD/AVG calculation: FIXED or SLIDE

(3)

. Select the desired type

(3)

by means of the “

” keys and confirm with “S”.

TIME

(4)

: select the time interval for the DMD/AVG calculation (5, 10,

15, 20, 30, 60 minutes). Select the desired time

(5)

by means of the

” keys and confirm with “S”.

FIXED SELECTION: if, for example, a time interval of 15 minutes has
been selected, the instrument will calculate the AVD/DMD value of the
measured variable and updates its value every 15 minutes.

SLIDING SELECTION: if for example a time interval of 15 minutes has
been selected, the instrument calculates the AVG/DMD value and
updates its value at the beginning after the first 15 values and then
after every minute, thus generating a window whose width is of 15
minutes and that moves forward every minute.

SYNCHRONISM

(6)

: select the synchronization mode, that is the

method that controls the calculation method of the average/demand
according to the selected time. Select the type of desired synchronism

(7)

by means of the “

” keys and confirm with “S”.

OFF

(7)

: the synchronization calculation starts when you switch the

instrument on.
CLOCK

(7)

: the synchronization starts as soon as the first selected

integration time multiple expires. Example: by setting the integration
time at 10 minutes and the current time at 10:25, the synchronization
will start at 10:30.
CONTACT

(7)

: the synchronization starts at the status modification

(from ON to OFF or from OFF to ON) of one of the digital inputs pro-
grammed such as SYNCHRONIZATION or TARIFF (see “DIGITAL
INPUTS”). A consequent status change produces the reset and then
again the starting up of the synchronization.

DMD/AVG calculation

WM5-96 Instruction Manual

**********MMAAIINN MMEENNUU**********

RREEVV.. 11..44..22..66 ((AAVV55))

SYSTEM
CT RATIO
VT-PT RATIO

DMD/AVG. CALCUL.

******DDEEMMAANNDD//AAVVEERRAAGGEE******

TYPE

TIME
SYNC

1

2

3

> 2s

> 2s

Measure

> 2s

******DDEEMMAANNDD//AAVVEERRAAGGEE******

TIPO

TEMPO
SINCRONISM

FIXED

SLIDE

******DDEEMMAANNDD//AAVVEERRAAGGEE******

TYPE

TIME

SYNC

4

5

> 2s

> 2s

******DDEEMMAANNDD//AAVVEERRAAGGEE******

TIPO

TEMPO

SINCRONISMO

5 min

10 min
15 min
20 min

******DDEEMMAANNDD//AAVVEERRAAGGEE******

TYPE
TIME

SYNC

6

7

> 2s

> 2s

******DDEEMMAANNDD//AAVVEERRAAGGEE******

TIPO
TEMPO

SINCRONISMO

OFF

CLOCK
CONTACT

Where:
Pmax is the maximum
power,
Pc is the contractual
power,
t1 is the selected time
period for the calcula-
tion of the AVG/DMD
value.

Go back

Go back

Confirm

Go back

Go back

Go back

Confirm

Confirm

Go back

Advertising