Programming wm5 96 – Carlo Gavazzi WM5-96 User Manual

Page 30

Advertising
background image

28

WM5-96 Instruction Manual

Programming WM5 96

This sub-menu allows the user to select which events are to be
stamped. Choose the function EVENTS SELEC.

(1)

by means of the

” keys and confirm with “S”. Afterwards proceed as follows:

ALARMS

(2)

: select if the alarm events are to be stamped. Choose

alarms by means of the “

” keys and confirm with “S”, then ,

alarm by alarm by means of the “

” keys, decide whether the

stamping is to be enabled “ON” or disabled “OFF”, by pressing the
“S” key.
MIN, MAX, DMD MAX

(2)

: select whether to store the minimum, max-

imum and dmd values for each variable measured by the instrument.
Select the minimum, maximum or dmd maximum by means of the “

” keys and confirm with “S”, then select, variable by variable if the

storing is to be carried out

(2b)

, choose by means of the “

” keys

the desired variable and decide whether to enable the storing “ON” or
disable the storing “OFF” by pressing the “S” key.
DIG. INPUTS

(2)

: select whether to store the status variables of the

digital inputs. Choose DIG. INPUTS by means of the “

” keys and

confirm with “S”, then select one by one the digital inputs of which the
storing is required

(2c)

, choose by means of the “

” keys the type

of digital inputs (remote, synchronism, tariff), then confirm whether to
enable the storing “ON” or disable it “OFF” by pressing the “S” key.
DIG. OUTPUTS

(3)

: select whether to store the status variations of the

digital outputs or not. Select the digital outputs by means of the “

keys and confirm with “S”, then confirm whether to enable the storing
“ON” or disable it “OFF” by pressing the “S” key.
RESET

(3)

: select whether the resets which have been carried out are

to be stored or not. Choose RESET by means of the “

” keys,

then select which resets are to be stored

(3b)

, by means of the “

keys and select whether to enable the storing “ON” or disable it “OFF”
by pressing the “S” key.

Events selection

************MMAAIINN MMEENNUU************

RREEVV.. 11..44..22..66 ((AAVV55))

DIGITAL INPUTS
DIGITAL OUTPUTS
ALARMS

EVENTS SELEC.

EEVVEENNTTSS SSEELLEECCTTIIOONN MMEENNUU

1

2

> 2s

> 2s

Measure

Measure

ALARMS

MIN
MAX

DMD MAX
DIG. INPUTS

********AALLAARRMM EEVVEENNTTSS********

2a

> 2s

Go back

ALARM 01 (OFF)

ALARM 02 (ON)
ALARM 03 (ON)

ALARM 04 (ON)
ALARM 05 (ON)

V1

(OFF)

v2

(ON)

V3

(ON)

VL

(ON)

V12

(ON)

2b

REMOTE (OFF)

SYNC

(ON)

TARIFF

(ON)

> 2s

Go back

> 2s

Go back

2c

EEVVEENNTTSS SSEELLEECCTTIIOONN MMEENNUU

> 2s

Go back

MAX
DMD MAX
DIG. INPUTS

DIG. OUTPUTS

RESET

3

REMOTE (OFF)

TOT. PAR.

(OFF)

TOTAL +

(ON)

TOTAL -

(ON)

PARTIAL +

(ON)

PARTIAL -

(ON)

PARTIAL +

(OFF)

PARTIAL -

(ON)

MIN - MAX

(ON)

DMD MAX

(ON)

LATCH (ON)

> 2s

Go back

> 2s

Go back

3b

3a

TOTALIZERS

(ON)

Advertising