Commands – Canon GALVANO GC-251 User Manual

Page 50

Advertising
background image

CANON Digital Galvano Scanner System

KP-1SM Series + GC-251

Users Manual 1.00

50

7. Commands

The controller has a monitor output (analog output) terminal for monitoring the RS-232C command

operation status and an external signal input terminal for controller operation.

7.1.

List of Commands

ID

Command Name

Data

Data

Return Value

0

Soft Reset

Yes

0: Auto homing
1: Reset only

1 Error

Clear

2 Homing

Start

4

Servo On

Yes

0: OFF
1: ON

7

Control Mode Specification

Yes

0: PI
1: LQ

8

Movement Start

Yes

0: Step move start
6: Initial position of raster scan

9 Forced

Stop

10

Target position Setting Mode

Yes

0: Absolute
1: Relative

11

Thermistor Temperature Read

Yes

0: Controller temperature
1: Motor temperature

A/D converted value
of thermistor voltage

12

Current Position Read

Yes

0: Current position
1: Current target value
(Program origin)
2: Current target value
(Absolute position)

Position (Pulse)

13

Version Read

Yes

0: Main DSP Ver
1: Sub DSP Ver

Ver. No

14 Status

Read

Status(16bit)

15

Error Read

Error (16bit)

18

Acceleration Control

Yes

0: OFF
1: ON

20

Target Position Setting

Yes

Target position (pulse)

22

Target Velocity Setting

Yes

Target velocity (pulse/second)

23

Operation Mode Setting

Yes

See “Command Details.”

26

Parameter Value Check

Yes

Parameter ID

Parameter value

30

Program Coordinate System

Yes

0: Z phase
1: Program origin

40

Monitor Output Selection
(A2 , A8)

Yes

0: Head1 A phase
1: Head2 A phase
2:Corrected A phase

Advertising