Configure library: snmp – Dell PowerVault TL4000 User Manual

Page 154

Advertising
background image

Note:

The TL2000/TL400 email address field cannot be empty (clear). The email
notification setup allows the user to turn off the feature by deselecting the
notify error

and notify warnings boxes. The user can add an invalid email

as long as the email address format is correct (i.e. [email protected]).

SMTP Server Address (IPv4 or IPv6)

Enter the address of the email server of the individual you would like to
receive the errors and/or warnings. This can be an IPv4 or IPv6 address,
or a host name and domain. If a host name and domain is listed, the IPv4
or IPv6 address will be resolved from the DNS using that name, and the
address will be stored rather than the name. If the address changes, a new
name or a new address will need to be entered.

Domain Name

Enter the Domain Name for your library. This field cannot be blank when
using email notification.

Note:

If you attempt to enter a blank value for the Domain Name, a
warning message will appear. It will say If you are using Email
Notification then a value is required for the Domain Name

.

Click one of the following:

v

Refresh

- to cancel the changes made to the screen.

v

Submit

- to apply the changes made to the screen.

Configure Library: SNMP

This page shows the current SNMP configuration of the library and allows
modification to the configuration. When a change is requested, a box checks to
confirm the changes.

Click SNMP in the left navigation pane to display the SNMP page.

Note:

For information about SNMP, see “SNMP Messaging” on page 1-7 and
Appendix F, “SNMP Status MIB Variables and Traps,” on page F-1.

Note:

If SNMP is not enabled (cleared), all SNMP fields are disabled.

a77ug278

Figure 5-49. Configure Library: SNMP page

5-56

Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide