Dell PowerVault TL4000 User Manual

Page 180

Advertising
background image

Table 7-1. Troubleshooting table (continued)

Problem

Solution

Determining current firmware
levels

Many problems can be resolved by a firmware upgrade. Ensure that both the
library and drive firmware are at the latest levels available.

v

Library firmware: Monitor > Library > Identity > Version

v

Drive firmware: Monitor > Drives > Identity (select a drive) > Firmware Rev

Update library firmware

Refer to “Service Library: Upgrade Firmware” on page 5-63.

Update drive firmware

Refer to “Service: Service (Drives)” on page 5-31 or “Service Library: Upgrade
Firmware” on page 5-63.

CARTRIDGE MOVEMENT PROBLEMS

Cartridge placement problems

Magazine slot prism fiducials NOT seated properly can result in gripper or slider
error codes due to the fiducial interfering with the back edge of the cartridge.
Release and pull magazines out of the library for inspection. To release the
magazines using the Operator Control Panel, navigate to Control > Magazine and
select Left or Right. To release the magazines using the Web User Interface,
navigate to Manage Library > Release Magazines.

Inspect the light pipe fiducials on each slot of the magazine for proper seating.

Cartridge will not eject from
drive

1.

Allow the drive to complete all operations. This may take as long as 1 hour if
you reset or cycle power on the library while the cartridge is positioned at the
physical end of the media.

2.

Ensure that the backup software is not reserving the slot or preventing the
drive from ejecting the cartridge. The backup software needs to cancel the
reservation and any hold it has on the drive. Temporarily disconnecting the
library from the host server and power cycling eliminates the host and its
software as a problem source.

3.

If the problem still exists, contact technical support.

Cartridge can not be removed
from storage slot

See “Removing Cartridges from Magazine Slots” on page 9-1.

MEDIA

Cleaning or data cartridge
incompatible with drive.

Ensure that you are using data and cleaning cartridges that are compatible with
the drive and model of your library. The library automatically unloads
incompatible cartridges and the Media Attention LED flashes. Export the media in
order to clear the state. Refer to “Cartridge Compatibility” on page 6-3.

Cannot write to or read from
tape.

1.

Ensure that the cartridge write-protect switch is in the write enabled position
(see “Write-Protect Switch” on page 6-6).

2.

Ensure that you have the appropriate data cartridge for your library model
(see “Cartridge Compatibility” on page 6-3).

3.

Ensure that you are using an Ultrium cartridge that has not been degaussed.
Do not degauss Ultrium cartridges.

4.

Ensure that the cartridge has not been exposed to harsh environmental or
electrical conditions and is not physically damaged in any way. Refer to
“Provide Proper Acclimation and Environmental Conditions” on page 6-8 and
“Perform a Thorough Inspection” on page 6-9.

5.

Many backup applications do not read or write to cartridges that were created
using a different backup application. In this case, you may have to perform an
erase, reformat, or label replacement operation on the cartridge.

6.

Ensure that you understand any data protection or overwrite protection
schemes that your backup application may be using, which could prevent you
from writing to a given cartridge.

7.

Retry the operation with a different, known good cartridge.

8.

Clean the drive. See “Service Library: Clean Drive” on page 5-58.

7-4

Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide

Advertising