Table 8-1. Main Error Codes (continued)

Error Code Description

User Action

DE

Warning Event! See Table 8-3 on page 8-11

DF

Warning Event! See Table 8-3 on page 8-11

E0

Incompatible magazine that is detected

1.

Remove magazine from library.

2.

Insert magazine in library. If error
recurs, contact technical support.

E2

New hardware found. Library firmware upgrades required.

Upgrade library firmware to the
latest version.

EB

Power supply health check failed because of a power supply
failure.

Refer to “Isolating a Power Supply
Problem” on page 7-7

F0

Drive Over temperature Condition

The subcode indicates which drive is affected.

Example:

Subcode 02: drive #2

1.

Check the ambient temperature
conditions, and check all fans.

2.

Refer to “Isolating Drive Sled
Problems” on page 7-9.

Chapter 8. Error codes