background image

Table 7-1. Troubleshooting table (continued)

Problem

Solution

Cartridge VOLSER is reported
as "unknown"

Probable cause: cartridge with no label or damaged label.

Ensure that cartridge is properly labelled. If cartridge is properly labelled, unload
the cartridge from drive and perform an inventory (OCP: Control > Re-Inventory;
Web: Manage Library > Perform Inventory). If VOLSER is again reported as
"Unknown", run Library Verify (Service > Library Verify).

DRIVE ID (SCSI, SAS, OR FIBRE CHANNEL LOOP)

Changed drive ID, but the host
server does not recognize the
new ID

1.

Ensure that all devices on the same bus/network have unique ID numbers.

2.

Ensure that you cycle power on the library after changing the ID.

3.

Reboot the host server.

Tape library performance: The
library is not efficiently backing
up data

1.

Check the network bandwidth from the host computer. If you are backing up
data over a network, consider comparing to a local-only backup.

2.

Ensure that the library and tape drive are on their own SCSI bus and not
daisy-chained to another tape drive or to the hard drive being backed up.

3.

Ensure that the library is connected to a LVDS SCSI bus and there are no
single-ended (SE) devices on the same bus, because this will cause the entire
bus to negotiate down to SE speed.

4.

Use an Ultra160 SCSI bus and high-quality cabling with the library.

CUSTOMER REPLACEABLE UNITS (CRU) AND SERVICE SPARES

Drive Sled

See “Isolating Drive Sled Problems” on page 7-9.

Power Supply

See “System Status” on page 2-6 and“Isolating a Power Supply Problem” on page
7-7.

Library Controller Card

See “Isolating a Library Controller Card vs. Accessor Enclosure Problem” on page
7-10.

Library Enclosure (Service
Spare)

See “Isolating a Library Controller Card vs. Accessor Enclosure Problem” on page
7-10.

ITDT

Performance Test duration
varies

Items affecting the duration of the test are:

v

The level of adapter device driver

v

Your adapter model and type

OTHER PROBLEMS

Web User Interface problems

See “Isolating Web User Interface Problems” on page 7-11.

Bar code scanner problems

See “Isolating Accessor Scanner Problems” on page 7-12.

Host Attachment Interface
problems

See “Isolating Host Attachment Interface Problems” on page 7-12

Need help with a library
password

Contact technical support.

Key path diagnostic not
working

This diagnostic is available with library firmware level greater than 6.xx. Refer to
“Verifying/Updating Firmware” on page 4-23 to determine the level of firmware
on your library. If necessary, visit http://support.dell.com to download the latest
levels of firmware for your library.

Auto Clean status displayed as
"Chk Media/Rsvd Slot?" on the
Web User Interface System
Status screen.

If Auto Clean is enabled and a cleaning cartridge is not present, or if a cleaning
cartridge is present but not in the reserved slot, Auto Clean status will show "Chk
Media/Rsvd Slot?" and Status will show a green check mark and the words
"Media Attention."

Chapter 7. Troubleshooting