Dell PowerVault TL4000 User Manual

Page 271

Advertising
background image

5.

Add the /LUNS switch to the load line of the appropriate SCSI driver. If a dual
channel card is installed and you are unsure which channel the LUN device is
attached to, simply edit both lines.

LOAD ADPT160M.HAM SLOT=201 /LUNS
LOAD ADPT160M.HAM SLOT=202 /LUNS

6.

After the STARTUP.NCF file has been edited, save the file and reboot the server
to activate the new STARTUP.NCF.

7.

Upon reboot navigate to the System Console and type scan all. This will start
a scan of all the LUNS on each adapter.

8.

When the scan is complete, verify the LUN device has been detected using the
list storage adapters command. Typical output with both the tape drive and
loader being recognized:

0x08 [V321-A3] Adaptec SCSI Card 39160/3960D - Ultra160 SCSI [slot 201]

0x16 [V321-A3-D5:1] DELL

PV-124T

0031

0x15 [V321-A3-D5:0] IBM ULT3580-TD3 5BG2

0x09 [V321-A4] Adaptec SCSI Card 39160/3960D - Ultra160 SCSI [slot 202]

Netware may display unbound device, meaning a driver is not bound to the
loader unless a driver from a backup software is loaded. This does not prevent
the backup application from detecting the LUN and binding the appropriate
driver.

Note:

The command scan all must be typed upon OS boot every time. If
backup software services automatically start on OS boot, you must
disable them, run the scan all command, and re-enable the services.

Appendix D. Enabling LUN Support in Linux

D-3

Advertising
This manual is related to the following products: