Dell PowerVault TL4000 User Manual

Page 261

Advertising
background image

Table C-2. LTO Tape Drive Sense Data (continued)

Byte

Bit Address or Name

7

6

5

4

3

2

1

0

12-13

Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Byte 12 Byte 13
ASC ASCQ
00

00 - No additional sense - The flags in the sense data indicate the reason for

the command failure

00

01 - Filemark detected - A Read or Space command terminated early due to an FM

The FM flag is set.

00

02 - EOM - A Write or Write File Marks command failed because the physical

end of tape was encountered, or a Read or Space command encountered EOM
The EOM flag is set

00

04 - BOM - A space command ended at Beginning of Tape

The EOM bit is also set

00

05 - EOD - Read or Space command terminated early

because End of Data was encountered

00

16 - Operation in Progress

04

00 - Cause not reportable - A cartridge is present in the drive, but it is in the

process of being unloaded

04

01 - Becoming Ready - A media access command was received during a

front panel initiated load or an immediate reported load command

04

02 - Initializing Command Required - A cartridge is present in the drive, but is not

logically loaded. A Load command is required

04

03 - Manual Intervention Required - A cartridge is present in the drive but could

not be loaded or unloaded without manual intervention

04

10 - Logical unit not ready, auxiliary memory not accessible

04

12 - Logical unit not ready, offline

08

01 - Logical unit communication failure

09

00 - Track following error (servo)

0C

00 - Write Error - A Write operation has failed. This is probably due to bad

media, but may be hardware related

11

00 - Unrecovered Read Error - A Read operation failed. This is probably due

to bad media, but may be hardware related

11

12 - Auxiliary memory read error. The drive reported that it is unable to read the

Auxiliary Memory in a WORM cartridge.

14

00 - Recorded Entity Not Found - A space or Locate command failed because

a format violation prevented the target from being found.

14

03 - End Of Data not found - A Read type operation failed because a format

violation related to a missing EOD data set

14

10 - Not Ready - Auxiliary memory not accessible. The drive is not able to become

ready because it is unable to access the Auxiliary Memory in a WORM cartridge.

17

01 - Recovered data with retries

1A

00 - Parameter list length error - The amount of parameter data sent is incorrect

20

00 - Invalid Command Operation Code - The Operation Code in the command

was not a valid Operation Code

24

00 - Invalid field in CDB - An invalid field has been detected in a

Command Descriptor Block

25

00 - LUN not supported - The command was addressed to a non-existent

logical unit number

26

00 - Invalid Field in Parameter List - An invalid field has been detected in the

data sent during the data phase

Appendix C. Sense Data

C-9

Advertising
This manual is related to the following products: