To setup alarm recording setting, Chapter 3.9.5 – AVer NXU Lite User Manual

Page 131

Advertising
background image

123

3.9.4

To Setup Alarm Recording Setting

1.

Beside the Start Recording check box, click Detail.

2.

In the Alarm Recording Setting dialog box, select the camera to enable/disable video recording.

Enable All to select all cameras.

3.

In the Frame Rate selection, select As Setting to record the number of frames based on the

Recording Setting or Max to record the maximum of frames based on the available speed

(maximum is 32 pictures)

4.

In the Start Recording prior text box, mark and set the number in second for the program to pre-

recording before the alarm happen. The time range is 1~10 seconds.

i

-

When IP camera and recording resolution less or equal to D1, the NVR system only

record in key frame for pre-recording.

-

When camera is Mega-pixel IP camera and the recording resolution is greater than D1,

the NVR

system won’t do any pre-recording.

5.

In the Stop Recording after text box, mark and set the number in second for the program to

continue recording after the alarm has ended. The time range is 1~600 seconds. If user doesn

’t

mark and set the time, the alarm recording will continue recording until alarm is reset.

6.

Click OK to accept the new settings and Cancel to exit without saving.

Advertising