153

Alarm Setting

In the Alarm Setting dialog box, click Add to insert and set new alarm setting, click Delete to remove
the selected alarm setting, click OK to exit and save the setting, Cancel to exit without saving, and
Default to revert back to original factory setting.

To set the Alarm Setting:

1.

Click Add to insert and set a new alarm setting. Click the items in the (8) Alarm Setting List, if

you want to modify the alarm setting.

2.

In (1) Alarm Setting number/Name/Description, display the selected alarm setting number in

the list below. Enter alarm name and description.

3.

In (2) Enable Time, the number from 00 to 23 represent the time in 24-hour clock. Select the time

and click the block you want to activate or deactivate the alarm function. When it is deactivated

the color of the block turns white.

4.

In (3) Conditions

, you can set “Trigger if any” to activate if it falls to one of the conditions or

Trigger if all” to activate if it falls to all conditions. In Camera section, select and click on the

camera number in Motion Detected and Video Loss to set the condition for the system to alarm.

5.

In (4) Sensor, select and click on the sensor number (use  and  to select the sensor) to set

the condition for the system to alarm. If the sensor normal status is high, set the sensor condition

to low.

- Enable/disable the Abnormal Event check box, to set the condition of the event for system to

alarm.

System Reboot: when the NVR system reboot without abnormal condition, the system

will send out the alarm message.