EFCO S5500 SSG User Manual

Page 33

Advertising
background image

EFCO CORPORATION 6/2012

PART NO. Y554

Series 5500 Silicone Structural Glazed Curtain Wall Installation Instructions

Section V: Glazing Installation

STEP #3 INSTALL ANTI-WALK BLOCKS

A. Stretch the anti-walk blocks until they are elongated enough to fit between the glass face

and the front face of the glazing pocket.

B. Install and position anti-walk blocks in the verticals at the center of each D.L.O. A tool such

as a standard screwdriver may be used to drive the spacer into the glazing pocket far

enough to clear the glass edge, so that it snaps back into shape once it is in the pocket.

DEEP POCKET ANTI-

WALK BLOCK

SHALLOW POCKET

ANTI-WALK BLOCK

STRETCHED ANTI-

WALK BLOCKS

Advertising