EFCO S5500 SSG User Manual

Page 34

Advertising
background image

EFCO CORPORATION 6/2012

PART NO. Y554

Series 5500 Silicone Structural Glazed Curtain Wall Installation Instructions

Section VI: Exterior Cover & Drive-In Gasket Installation

STEP #1 INSTALL DRIVE-IN GASKETS IN VERTICAL MULLIONS

A. Remove the exterior drive-in wedge gasket material from the reel, and allow the gasket to

relax and shrink.

B. Remove any temporary retainer gaskets previously applied, from the opening at hand.
C. The exterior vertical gaskets must be cut vertical D.L.O. plus 1 3/4”. Apply the drive-in gas-

kets at the vertical mullions by driving in the wedge gasket, starting at the center of the

D.L.O. Crowd in the excess at the ends. Care should be taken not to stretch the gasket when

installing. The vertical gaskets should run through and extend past the horizontal gaskets,

once the horizontal gaskets are in place.


INTERMEDIATE SHOWN, HEAD AND SILL SIMILAR

Apply drive-in wedge

gaskets at verticals (cut

D.L.O. plus 1 3/4”).

Advertising