4 digital i/o – Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 16

Advertising
background image

12

Installation/Operation Manual

2.4

Digital I/O

Digital inputs can be set to provide many batching functions on the CB-2. Digital inputs are active low (0 VDC),

inactive high (5 VDC).
Digital outputs are typically used to control relays that drive other equipment. Outputs are designed to sink,

rather than source, switching current. Each output is a normally open collector circuit, capable of sinking 24 mA

when active. Digital outputs are wired to switch relays when the digital output is active (low, 0 VDC) with

reference to a 5 VDC supply.
Table 2-5 shows the pin assignments for connector J2 which is located on the CB-2 CPU board.

Table 2-5. J2 Pin Assignments (Digital I/O) on CB-2 Main Board

J2 Pin

J2 Signal

Function

1

+5 VDC

2

GND

3

DIO 1

Emergency Stop

4

DIO 2

Manual Mode

5

DIO 3

Remote Start

6

DIO 4

Remote Pause

Digital inputs and outputs are configured using the DIG I/O menu. See Section 3.1 on page 18 for configuration

information.Table 2-6 through 2-9 lists the digital I/O channels and their pre-defined functions for the CB-2.

Digital I/O

Location

Type

Description

Terminal #

Setpoint

Slot 3

Bit 1

Digital Output

Aggregate 1 Batch

3-1

SP1

2

Aggregate 2 Batch

3-3

SP2

3

Aggregate 3 Batch

3-5

SP3

4

Aggregate 4 Batch

3-7

SP4

5

Aggregate 5 Batch - Option

3-9

SP5

6

Aggregate 6 Batch - Option

3-11

SP6

7

Aggregate 7 Batch - Otion

3-13

SP7

8

Aggregate 8 Batch - Option

3-15

SP8

9

Aggregate Discharge Open

3-17

10

Aggregate Discharge Closed

3-19

11

Aggregate Vibrator

3-21

12

Sand Bin Vibrator

3-23

13

Cement 1 Batch

3-25

SP9

14

Cement 2 Batch

3-27

SP10

15

Cement 3 Batch

3-29

SP11

16

Cement 4 Batch

3-31

SP12

17

Dust Collection

3-33

18

Alarm/Horn

3-35

19

Aggregate Conveyor Start

3-37

20

Aggregate Conveyor Stop

3-39

21

Cement Discharge Open

3-41

22

Cement Discharge Closed

3-43

23

Cement Vibrator

3-45

24

Weigh Hopper Aeration

3-47

Table 2-6. Digital I/O Pin Assignments for Slot 3