Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 31

Advertising
background image

Installation/Operation Manual - Configuration of User Parameters

27

Water Adjust per Batch

No
Yes

Yes if the water adjustment amounts are to be per batch, No if they are to be
per yard/cubic meter.

Admix System

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/ADMIX SYSTEM

Suspend Admixture Addition

No
Yes

Set this to Yes to inhibit the adding of all admixtures without changing the mix
designs.

Single Empty Signal

No
Yes

Yes if Admixture 1 Bottle Empty on indicates all bottles are empty.

Mixing System

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/MIXING SYSTEM

Enable Mixer Controls

No
Yes

Set to Yes if a mixer is part of your system and you wish to have the CB-2
control it.

Auto Start/Stop Mixer

No
Yes

If Yes, the CB-2 will control the running of the mixer.

Mixer Start is Latched

No
Yes

If Yes, the CB-2 will pulse the Mixer Start output on for two seconds to start

the mixer and pulse the Mixer Stop output to stop the mixer.

Otherwise, the Mixer Start output is set on and held on to run the mixer.

Auto Discharge Mixer

No
Yes

If Yes the CB-2 will control the discharge of the mixer.

Power Discharge Gate to Close

No
Yes

If Yes, CB-2 will set the Mixer Gate Close output on to close the mixer
discharge gate.

Discharge Gate Close Time

3.0

Time in seconds for the mixer discharge gate to open/close. If Power
Discharge Gate to Close was set to Yes, this is the amount of time the Mixer
Gate Close output will be held on. If Gate Open Limit Switch is set to No and
Power Discharge Gate to Close to Yes, this is the amount the Mixer Gate
Open output will remain on to open the gate.

Mixer Discharge Time

8.0

Maximum time in seconds for the mixer to discharge.

Gate Closed Limit Switch

No
Yes

If Yes, CB-2 will use the Mixer Gate is Closed input to recognize that the gate
is closed.

Gate Open Limit Switch

No
Yes

If Yes, CB-2 will use the Mixer Gate is Open input to recognize that the gate is
open.

Ticket/Reports Setup

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/TICKETS & REPORTS SETUP

Print Custom Batch Ticket

No
Yes

Print Custom Batch Ticket (requires special software)

Print Ticket Number

No
Yes

Select Yes to print the batch ticket number on the batch ticket.

# Line Feeds

Number of initial lines to space to reach correct starting location.

DOT Header

“Certificate of Compliance”

This string will be printed at the head of any ticket printed for an order that has
it’s DOT parameter defined as other than None.

Source Length

6

Maximum printable material source length.

ADMIN Menu

Parameter

Choices

Description

Table 4-1. Application Parameters Sub-menu List