Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 39

Advertising
background image

Installation/Operation Manual - Configuration of User Parameters

35

Zero Tolerance Band

On a hopper type scale, the tolerance band for the initial empty condition

Cleanout Time

On a hopper type scale, amount of time in seconds to keep the discharge
gate open after it has reached the empty level to allow it to totally empty.

Close Time

For scales with a discharge gate that does not have a limit switch, the amount
of time in seconds the gate takes to close.*

Discharge Delay

Time in seconds after the discharge cycle begins before this scale’s
discharge is to begin

Start Discharge % Full

For the cement scale, this indicates the % of the aggregate remaining to be
discharged before the cement discharge will begin. This parameter is ignored
for the aggregate or water scales

Target Discharge Rate

Start Vibrator Weight

Weight below which the vibrator will be operated

Wide Open Weight

For a hopper type scale, the weight below which the inching gate will be

opened fully.
For the aggregate scale, if the cement scale is still discharging when the
remaining total aggregate weight to be discharged drops below this weight,
the aggregate discharge gate will be closed until the cement hoper has
finished discharging

Gate Open Time

Time in seconds for the discharge gate to open fully.*

Inch Time

Time in milliseconds to pulse the open or close output to inch an inching
gate.*

Initial Burst Time

Time in seconds to hold on the open output to initially open an inching gate.*

Control Rate Filter

Number of samples to average to calculate the flow rate

Discharge Rate Tolerance

Discharge rates within this tolerance % of the target rate will not cause any
gate adjustment..

Total Under Tolerance

Percentage of total weight the scale may be below the total target.

Total Over Tolerance

Percentage of total weight the scale may be above the total target

Discharge Controls

Connection to additional scale data

* For decumulative scales with more than one material bin, these values are specified with the “location” definition for the individual
materialsm

Gate Open Output

Digital output address of port used to open the discharge gate

Gate Close Output

Digital output address of port used to close the discharge gate

Vibrator Output

Digital output address of port used to run the vibrator.

Aerator Output

Digital output address of port used to run the aerator during the discharge

Limit Switch Present

No
Yes

Discharge gate closed limit switch exists

Limit Switch Input

Digital input address of port used to receive the gate closed limit switch signal

Gate Type

Open/Closed
Inching
Skiphoist

Discharge gate is either simple open/closed or inching type or skiphoist.

Skip Hoist Up Control

Output port for signal used to move bucket to top posit

Skip Hoist Down Control

Output port for signal used to move bucket up to 75% position

Skip Hoist Mid Control

Output port for signal used to return bucket to bottom position

Skip Hoist Up Signal

Input port for signal that bucket is in top position

Skip Hoist Down Signal

Input port for signal that bucket is at 75% position

Skip Hoist Mid Signal

Input port for signal that bucket is in bottom position

Mixes

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/MIXES

ADMIN Menu

Parameter

Choices