Installation/Operation Manual
10.10 CB-2 Loss In Weight Open/Close
When configuring the CB-2 for an open close gate it is important to know the time in seconds required to fully
open and close the inching gate. Manually open the discharge gate and record the amount of time in seconds
required to fully open the gate. Repeat a few times for accuracy. Average the time readings and this number will
represent the “fully open time” for the gate. This process can be reversed to calculate the “fully closed time.
Admin Menu
Databases
Scales
Aggregate
SCALE TYPE = DECUMULATIVE
CLOSE TIME = Time in seconds
GATE OPEN TIME = 3 SEC
INCH TIME = 0
CONTROL RATE FLTR = 0
TARGET DISCH RATE = 0
DISCHARGE RATE = 0
TOLERANCE
Discharge controls
GATE TYPE = OPEN/CLOSE
With gate “open/close” selected, inch time needs to be set to “0”.
Admin Menu
Data bases
Scales
Aggregate
Inch time = 0