Installation/Operation Manual

10.3 Weighing Material Preact Configuration Parameters

Admin menu

Data bases

Materials

(Desired material)

Preacts

LEARN PREACT = OFF

PREACT WEIGHT BAND = Calibrated scale capacity / 10

LEVEL 1 thru 10 PREACT = (Please see description below)

10.3.1

Preacts - Hopper Scale

Admin menu

Data bases

Scales

(Desired scale)

SCALE TYPE = HOPPER

The preact value for a weigh hopper scale must vary with the batch size (hopper level). Concrete batching

systems batch size may vary from a fraction to multiple cubic yards or meters. The CB-2 “PREACT WEIGHT

BAND” parameter equals the calibrated scale capacity / 10. Example: 10,000 lb calibrated scale capacity / 10 =

1000. The CB-2 will associate preact values 1 thru 10 with scale target values
0-1000 lb., 9001-10000 lb. The lowest hopper level (smallest batch size) will be associated with the longest

“material in flight” time requiring the largest preact value. The following example represents the association

between preact weight band and possible preact levels.
PREACT WEIGHT BAND = 1000 (10,000 calibrated scale capacity / 10)

Table 10-1. Preact Level Values

Target Value

Preact Level

Preact Level Value

0000 - 1000

1

550

1001 - 2000

2

500

2001 - 3000

3

450

3001 - 4000

4

400

4001 - 5000

5

350

5001 - 6000

6

300

6001 - 7000

7

250

7001 - 8000

8

150

8001 - 9000

9

150

9001 - 10000

10

100

The preact level values will have to be determined for each material. Mix designs structured with one material

only containing target values ranging from low to high ran automatically with jogging turned off will determine

the preact level values. The amount over the target value should be entered for the appropriate preact level.