Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 36

Advertising
background image

32

Installation/Operation Manual

Jogging

Jogging is used to add small increments of material to reach or exceed the target weight.

The jog levels are used to adjust the amount of time the open gate control will be held on depending on how

far we are from the target weight.

If we are within the Jog Tolerance, no jogging will be done. Otherwise, the distance from the target will be
used to determine the jog level, and the jog level is used to determine how much time (0.00 to 0.80 seconds)
is to be added to the minimum jog time to determine the actual jog time.

Jog Mode

Off
On

Used to disable / enable jogging

Maximum Number of Jogs

10

Maximum number of jogs allowed

Jog Off Time

2.00

Settling time between jogs. This is the amount of time it takes for the jogged
material to arrive on the scale.

Jog Tolerance Weight

20

No Jog target tolerance weight

SS Flow Rate

0

Unused

Minimum Jog Time

0.25

Minimum jog on interval in seconds

Maximum Jog Time

1.5

Maximum jog time in seconds

Level 1 Jog Weight

50

Maximum remaining weight for jogging at minimum jog time

Level 2 Jog Weight

150

Maximum remaining weight for jogging at minimum jog time + 0.05 seconds

Level 3 Jog Weight

Maximum remaining weight for jogging at minimum jog time + 0.10 seconds

Level 4 Jog Weight

200

Maximum remaining weight for jogging at minimum jog time + 0.15 seconds

Level 5 Jog Weight

300

Maximum remaining weight for jogging at minimum jog time + 0.20 seconds

Level 6 Jog Weight

400

Maximum remaining weight for jogging at minimum jog time + 0.25 seconds

Level 7 Jog Weight

500

Maximum remaining weight for jogging at minimum jog time + 0.30 seconds

Level 8 Jog Weight

600

Maximum remaining weight for jogging at minimum jog time + 0.35 seconds

Level 9 Jog Weight

700

Maximum remaining weight for jogging at minimum jog time + 0.40 seconds

Level 10 Jog Weight

800

Maximum remaining weight for jogging at minimum jog time + 0.50 seconds

Level 11 Jog Weight

900

Maximum remaining weight for jogging at minimum jog time + 0.60 seconds

Level 12 Jog Weight

1000

Maximum remaining weight for jogging at minimum jog time + 0.70 seconds

Locations

You have the ability to Add, Copy, Change, Delete or Exit

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/LOCATIONS

Location ID

ID used to reference this location

Name

Location name

Material

Material ID of material dispensed from this location

Delivery Mode

Single Speed

Dual Speed

Dual Concurrent

Inching Gate

Bottle Admix

Direct Admix

Reservoir Water
Direct Water

Select the method used to deliver the product at this location. The setting of
this parameter will determine which of the following parameters are
presented.

Delivery Mode = Single Speed, Dual Speed, or Dual Concurrent

Secondary Mode

Off

Continuous Aeration

No Flow Aeration

Continuous Vibrator
No Flow Vibrator

Chose aeration or vibrator and whether they should be used continuously or
only when material stops flowing

Scale

Scale ID of scale used to weigh material

ADMIN Menu

Parameter

Choices

Description