Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 30

Advertising
background image

26

Installation/Operation Manual

Start Allowed in ‘Manual’ mode

No
Yes

Select Yes to allow a batch to be started while in Manual mode.

Jog and Correct Last Batch Only No

Yes

If Yes is selected, jogging will only be done on the final batch of a split batch
load.

Batcher Air After Weigh-up

No
Yes

Select Yes to have the cement weigh hopper aeration start just after the last
ingredient is weighed on the cement scale.

Delete Load Rec After Load

No
Yes

If no is selected the load record will be retained after the load has been
processed.

Batching Limits

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/BATCHING LIMITS

Maximum Plant Capacity

10.0

Maximum plant capacity in yard/cubic meters.

Minimum Plant Capacity

0.25

Smallest allowable quantity. Must not be greater than 1/2 of the maximum
plant capacity.

Total Yards (Daily)

These four values are accumulators maintained by the CB-2. The time frames
(daily, weekly, etc) are arbitrary. Each value contains the amount batched
since the last time it was set to zero.

Total Yards (Weekly)

Total Yards(Monthly)

Total Yards (Yearly)

Water System

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/WATER SYSTEM

Weighed Water

No
Yes

No for metered water, Yes for weighed. The default for a two scale system is
No and for a three scale system is Yes.

Water Reservoir

No
Yes

Yes if water is to be metered into a reservoir, No if water is weighed or directly
metered into the truck or mixer.

Start Water with Weigh-up

No
Yes

Yes if water can be dispensed into the truck or mixer while the other materials
are being weighed.

Water to Truck/Mixer First

No
Yes

Yes to discharge all head water (excluding tail water) into truck/mixer before
aggregates and cement are added.

Start Water With

Discharge

Manual

Cement Discharge

Aggregate Discharge

Skiphoist Discharge

Weighup

Material 1
Material n

Discharge will automatically start the front water discharge at the beginning of

the discharge cycle.

Manual will display a Start Water softkey during weigh-up to allow the

operator to begin dispensing water before the other materials have been

weighed. (If the water discharge has not begun before the discharge cycle

begins, the water is added at that point.)

Cement Discharge will start the front water discharge when the cement

discharge begins.

Aggregate Discharge will start the front water discharge when the aggregate

discharge begins.

Skiphoist Discharge will start the front water discharge when the aggregate

skiphoist discharge begins.

Weighup will start the water discharge while the other materials are being

weighed.
Select a material to start adding the water when the weigh up of that material
begins.

Suspend Water During Cement

No
Yes

Yes will suspend water and admixture discharge while cement is being
discharged.

Percent Tailwater

20

Percent of total water to be added after all other materials have been added
to the truck or mixer.

Minimum Tailwater Amount

20 gal/160 lb

Minimum amount of tailwater.

Truck Washout Amount

300 gal/2500 lb

Amount of water to be used to do a truck washout (code 9274).

ADMIN Menu

Parameter

Choices

Description

Table 4-1. Application Parameters Sub-menu List

Advertising