Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 42

Advertising
background image

38

Installation/Operation Manual

Intervals & Timers

ADMIN Menu

Parameter

Choices

Description

Level 2 Sub-menu

INTERVALS & TIMERS

Level 3 Sub-menu ADMIN MENU/INTERVALS & TIMERS

Max Time Between Pulses

5

Maximum time in seconds between pulse inputs for metered water or
admixture.

Start Conveyor Warning Time

5

Time in seconds alarm is to remain on before aggregate conveyor is started .

Agg Conveyor Run-out Time

5

Time in seconds aggregate conveyor is to remain running after aggregate
discharge is complete

Print Line Delay

0.1

This feature is currently unsupported.

Beep Duration

0.5

CB-2 “Beep” time, in seconds.

Display Time

2

Time in seconds a message remains on the screen.

Data Entry Timeout

180

Maximum time in seconds CB-2 will wait for operator data entry

Configuration Exit Timeout

300

Time in seconds CB-2 will wait in configuration mode with no operator action

Password Timeout

20

Time in seconds after exiting configuration mode that operator may re-enter
without requiring password entry.

Auto Sequence Delay

1

In diagnostic mode, time in seconds each input or output is displayed.

Skip Hoist Dump Time

5

Minimum time in seconds the skip hoist bucket is to be held in the dumping
(top) position. Default = five seconds