Intervals & Timers
ADMIN Menu
Parameter
Choices
Description
Level 2 Sub-menu
INTERVALS & TIMERS
Level 3 Sub-menu ADMIN MENU/INTERVALS & TIMERS
Max Time Between Pulses
5
Maximum time in seconds between pulse inputs for metered water or
admixture.
Start Conveyor Warning Time
5
Time in seconds alarm is to remain on before aggregate conveyor is started .
Agg Conveyor Run-out Time
5
Time in seconds aggregate conveyor is to remain running after aggregate
discharge is complete
Print Line Delay
0.1
This feature is currently unsupported.
Beep Duration
0.5
CB-2 “Beep” time, in seconds.
Display Time
2
Time in seconds a message remains on the screen.
Data Entry Timeout
180
Maximum time in seconds CB-2 will wait for operator data entry
Configuration Exit Timeout
300
Time in seconds CB-2 will wait in configuration mode with no operator action
Password Timeout
20
Time in seconds after exiting configuration mode that operator may re-enter
without requiring password entry.
Auto Sequence Delay
1
In diagnostic mode, time in seconds each input or output is displayed.
Skip Hoist Dump Time
5
Minimum time in seconds the skip hoist bucket is to be held in the dumping
(top) position. Default = five seconds