Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 74

Advertising
background image

70

Installation/Operation Manual

Parameter Name Duplicate Value

The specified parameter value must be unique and the entered value was already in use.

Error Detected - Check Printer For
Report

The data diagnostic utility detected errors in the database.

Error! Can’t Find Order #n

The specified order number (n) was not found in the orders database.

Error! Loads Database Full

The maximum number of loads record (1000) has been reached - no more loads may be
scheduled until some records are deleted. Please press 25623 and press enter to clear
the loads data base. When Confirm clear loads data base is displayed, press Yes.

EStop Pressed, No Discharge

The discharge softkey was pressed while the EStop button was in its down position.

EStop Pressed, No Restart

The Restart softkey was pressed while the EStop button was in its down position.

EStop Pressed, No Start

The Start softkey was pressed while the EStop button was in its down position.

Find Order Failed

The order record to be deleted was not found in the orders database.

Parameter Name Format is Invalid

The entered data is not in the correct format for the specified parameter.

Greater Than Plant Capacity

The size of the requested load is greater than the defined plant capacity. Increase plant
capacity in the batching limits section of the Admin menu.

Invalid Action

This is a system error that should not normally occur. Contact your service representative.

Invalid Date

Either the system date or the delivery date entered for an order was invalid.

Invalid Field Selection

This is a system error that should normally not occur. Contact your service representative.

Invalid Material Type

The material type was not either weighed or metered. Most likely indicates a corrupt
materials database.

Invalid Order Quantity

The entered order quantity was either greater than 10000 or less than or equal to 0.

Invalid Password

The password entered when trying to enter CB-2 setup mode was incorrect.

Invalid Port (1-4 only)

The CB-2 only supports serial ports 1 thorugh 4.

Invalid Range of Mix IDs

The ending mix ID number for a request for a mix design report for a range of mixes was
less than the initial ID.

Invalid Scale Weight

One of the scales is reporting an error state.

Invalid Slump

The valid range for the slump is 1 to 14 (or 2 to 36 in metic systems)

Invalid Time

Either the system time or the delivery time entered for an order was invalid.

Invalid Value

The new password value is not in integer

Parameter Name is Invalid

Invalid keyword.

SBB is Not a Digital Input

The entered slot and bit is not a valid digital input port address.

SBB is Not a Digital Output

The entered slot and bit is not a valid digital output port address.

Jog Record Not in Database

A weighed material had no matching record in the jogs database. this probably indicates
a corrupt jogs or material database.

Late Discharge

An admixture missed its add point. This might occur, for instance, if an admixture was to
be added with the weigh up of a specific material and that material was not incuded in the
current mix design.

Less Than Already Supplied

An attmept is being made to adjust the required amount for an order to less than what
has already been delivered.

Load ID Not in Database

This is a system error that should not normally occur. contact your service representative.

Load Index Out of Range

This is a system error that should not normally occur. Contact your service representative.

Load Too Big For Plant

The size of the requested load is greater than the defined plant capacity.

Load Too Small to Batch

The size of the requested load is less than the minimum batch size for the plant.

Loads Database Error

An error occured while trying to add a load record to the loads database.

Parameter Name Longer Than NN

The string type parameter was longer than the specified maximum

Problem

Description

Table 10-2. Error Codes