68

Installation/Operation Manual

CEMENT
Admin Menu

Databases

Locations


Material Location

Delivery Mode

Dual Speed (or) Dual Concurrent
To change the slot and bit numbers use the following steps.

1. Navigate down to the Fast Feed Gate and Slow Feed Gate using the

down

arrow on the 920i.

2. Press the

Change

softkey to change the parameters. The slot and bits are displayed together on the screen.

Press the

CLR

key on the 920i to erase the current slot and bit and then type in the desired slot and bit using the

numeric keypad on the 920i like the example shown for the Aggregate.
FAST SLOW FAST FEED SLOW SPEED
FAST SPEED SLOW SPEED FEED GATE FEED GATE SETPOINT SETPOINT
CEM 1 CEM 1 Batch CEM 1 Aux Slot 3, Bit 13 Slot 8, Bit 9 9 13
CEM 2 CEM 2 Batch CEM 2 Aux Slot 3, Bit 14 Slot 8, Bit 10 10 14
CEM 3 CEM 3 Batch CEM 3 Aux Slot 3, Bit 15 Slot 8, Bit 11 11 15
CEM 4 CEM 4 Batch CEM 4 Aux Slot 3, Bit 16 Slot 8, Bit 12 12 16

D u a l
Concurrant
C e m e n t
Batch

Make certain slot 8 bits 9 thru 12 are defined as “OUTPUT” and setpoint 13 thru 16 have have “SLOT” set to 8

and “DIGOUT” set to 9 thru 12 respectively.

The 920i indicator will be in “CONFIG” mode for this
check. Parameters are under “DIG I/O” & “SETPTS”.

DIG I/O SETPTS
SLOT 8 SP CFG
BIT (9-12) SET PT (13-16)
“OUTPUT” GROSS

SLOT (8) DIGOUT (9-12)