10.9 CB-2 Loss In Weight Inching Gate

When configuring the CB-2 for an inching gate it is important to know the time in seconds required to fully open

and close the gate. Manually open the discharge gate and record the amount of time in seconds required to fully

open the gate. Repeat a few times for accuracy. Average the time readings and this number will represent the

“fully open time” for the gate. This process can be reversed to calculate the “fully closed time”.

Admin Menu

Databases

Scales

Aggregate

SCALE TYPE = DECUMULATIVE

Discharge controls

GATE TYPE = INCHING

Admin Menu

Databases

Location

(Aggregate 1)

Delivery Mode = Inching gate

Open Gate = Slot 3, Bit 01

Close Gate = Slot 3, Bit 05

Gate Open Time = as recorded

Gate Close Time = as recorded

Inch Time = (Keep in mind “gate open/close time” when selecting entry. Start with 30ms)

Initial Burst Time = (Keep in mind “gate open time” when selecting entry. Start with .1 sec)

Slot 3 bit 01 thru 04 represent open gate for agg 1-4
Slot 5 bit 05 thru 08 represent close gate for agg 1-4