17 adding counter and position indicators, 6hulhv, Gglqj frxqwhu dqg srvlwlrq lqglfdwru – Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 87: Type series 521, Setting of the operatingparameters, Programming routine, Description, Inputs, Optocoupler output

Advertising
background image

Installation/Operation Manual - Appendix

83

10.17 Adding Counter and Position Indicators

 6HULHV

$GGLQJ FRXQWHU DQG

SRVLWLRQ LQGLFDWRU

Type series 521

npn: switching to 0 V

pnp: switching to
+V(4-30)

4.1 Input polarity

4.2 Activating the 30 Hz filter

max. count frequency
10 kHz

max. count frequency
30 Hz

Quadrature input
INP A: count input 0°
INP B: count input 90°

Quadrature input with
pulse doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted

Count input and count
direction input
INP A: count input
INP B: count direction input

4.3 Input mode

Differential input
INP A: count input adding
INP B: count input subtracting

4.4 Scaling factor (Multiplier)

Factor can be set from
00.0001 up to 99.9999. The
decimal point is fixed “0“
won’t be accepted!

KESSLER-ELLIS PRODUCTS

KESSLER-ELLIS PRODUCTS

KESSLER-ELLIS PRODUCTS

KESSLER-ELLIS PRODUCTS

KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724
Toll Free:800-631-2165 • Fax:732-935-9344

99631 4/9/98

3. Setting of the operatingparameters

a.

Hold down keys on front panel and switch on the
supply voltage.

b.

The display shows

c.

After releasing the keys the display alternates
between menu title and corresponding menu item at
a frequency of 0.5 Hz. After any key is pressed down,
only the menu item is displayed.

d.

Pressing the right key, the menu item will be
switched to next value.

e.

Hold down the left key and press the right key to
enter and switch to the next menu title.

f.

After programming the last menu item, the
programming routine will be left and the new values
will be stored by switching the menu item to „YES“. If
you chose „NO“, the programming routine will be
passed through once again.

4. Programming routine

Programmable parameters are shown in succession. After
one pass, the device is fully programmed.
In each case the first shown item is the factory preset.

1. Description

6digit adding counter, resetable

LED-Display with 8 mm high characters and very
high luminosity

Display range -199999..999999 (overflow condition
will be indicated by flashing of the display)

Programming of count functions and operating
parameters via the setting keys. During programming
the display guides the user with text prompts.

Optocoupler output (as option). Active at count
values <

0.

Programmable features:
Input polarity (npn or pnp)
Max. count frequency (30 Hz or 10 kHz)
Input mode
Decimal point
Scaling factor
Reset mode:

electrical
manual
manual and electrical
no reset

Set value (Goes to selected

value at reset.)

2. Inputs

INP A
Dynamic count input. Max. count frequency 30 Hz or
10 kHz programmable via set up
INP B
Dynamic count input. Max. count frequency 30 Hz or
10 kHz programmable via set up

RESET

Dynamic reset input. Linked to the red reset key.

3. Optocoupler Output

Active if count value < 0. Simple preset counter can be
realized, when using subtract mode.

Advertising