Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual

Page 38

Advertising
background image

34

Installation/Operation Manual

Usage Data

Access to usage data for location

Delivery Mode = Direct Admix

Admix #

Metering Output

Digital output address of port used to operate the metering device

Pulse Meter Signal

Digital input address of port used to receive the meter pulse

Pulse Counter SP

Pulse counting setpoint number

Usage Data

Access to usage data for location

Delivery Mode = Reservoir Water

Water #

Water counter number

Fill Reservior

Digital output address of port used to fill the reservoir

Reservior Discharge

Digital output address of port used to discharge the reservoir

Tailwater Discharge

If a separate tailwater reservoir compartment exists, digital output address of
port used to discharge the reservoir tailwater

Reservior Empty Sensor

Digital input address of port used to receive the reservoir empty signal

Pulse Meter Signal

Digital input address of port used to receive the meter pulse. This must be the

same as the digital
Input counted by the setpoint specified in the next (Pulse Counter SP)
parameter

Pulse Counter SP

Pulse counting setpoint number

Usage Data

Access to usage data for location

Delivery Mode = Direct Water

Water #

Water counter number

Metering Output

Digital output address of port used to operate the metering device

Pulse Meter Signal

Digital input address of port used to receive the meter pulse

Pulse Counter SP

Pulse counting setpoint number

Usage Data

Access to usage data for location

Location Usage Data

Daily Material Used

Daily Dispensed Accumulator

Weekly Material Used

Weekly Dispensed Accumulator

Monthly Material Used

Monthly Dispensed Accumulator

Yearly Material Used

Yearly Dispensed Accumulator

Material On Hand

Material on Hand

Last Daily Reset Time

Time and date daily material accumulator most recently reset

Last Weekly Reset Time

Time and date weekly material accumulator most recently reset

Last Monthly Reset Time

Time and date monthly material accumulator most recently reset

Last Yearly Reset Time

Time and date yearly material accumulator most recently reset

Scales Select or Enter scale number. 1-Agg, 2-Cement

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/SCALES

Scale Number

ID number used to reference this scale.

Name

Scale name (30 characters maximum)

Capacity

Maximum scale capacity

Scale Type

Hopper
Decumulative

Select the type of scale – either hopper or decumulative. Hopper scales

operate by discharging a material into the hopper until the target weight has

been reached and then dumping the hopper into the truck or mixer.
A decumulative scale has the full bin or bins on the scale and discharges the
correct amount of material(s) directly into the truck or mixer.

ADMIN Menu

Parameter

Choices

Description

Advertising