1.4 Specifications

Accuracy

±(0.1% +1d). ‘d’ equals one displayable increment.

Resolution

Standard displayed resolution: 2500-3750’d’. Resolutions to
10000’d’ (non LFT units only) are possible. Internal A/D resolution
24 bits.

Standard
Capacities

lb 250 500 1000 2000 5000 10,000 15,000
kg 125 250 500 1000 2500 5000 7500

Power

Battery operated, 6V rechargeable sealed lead acid battery pack
(standard Challenger Charger) Typically 50 hours of battery life with
automatic sleep mode and automatic power off.

Display

Five digit, large 1.5 in (38 mm) numeric red GaAIAs Light Emitting
Diode (LED)

Operating Temp

-40°F to +122°F (-40°C to +50°C), LFT range -10°C to +40°C

Operating Time

50 hours typical/100 hours max. (depends on operating mode)

Enclosure

NEMA 4/IP65 powder coated alodined cast aluminum

Load Cell

Standard 350 Ω Bridge, S-Beam

USER

Programmable multifunction button for use as

TEST, TOTAL, UNIT, PEAK, NET/GROSS, VIEW TOTAL, LEARN
(for RF Remote Control), HI-RES

CAL

Front panel calibration switch (located behind wire sealable screw)
Initiates full digital calibration procedure

Auto Zero
Maintenance

Standard, can be disabled internally

Auto-Off Mode

Prolongs battery life by turning POWER off after 15, 30, 45 or 60
minutes (operator determined) of no scale activity

Auto-Sleep Mode

Prolongs battery life by dimming LED display after 5, 15, or 30
minutes of no activity

Units

kg, lb (other units available with custom calibrations)

Filtering

Selectable: OFF, Low (LO), Medium (HI-1), High (HI-2)

Totalization

Standard: Press button or automatic; TOTAL weight up to 99999 X
1000 kg or lb

Peak

Uses unfiltered faster reading of A/D, (>220 readings per second)

Setpoints

Three internal standard setpoints and three ultra bright LEDs on
front panel

Service Counter

Two independent 32 bit registers; register 1 updated each time
weight exceeds 25% of capacity; register 2 updated each time
weight exceeds overload; when register 1 exceeds 16383 or
register 2 exceeds 1023, display reads “Cnt” for load cell counter;
Test function shows the two readings in order

Construction

All of these features are housed in a single, low-profile, cast
aluminum housing consisting of three sections:
The front of the scale houses the display, controls and all
electronics
The center section contains the load cell, lifting eye and hook
The rear of the scale features a quick access battery compartment

Table 1-1. Specifications