Rice Lake MSI-3460 Challenger 3 User Manual
Page 53
Appendix 49
Display toggles
between “Error” and
“buttn”
A key is stuck or is being held
down.
Check switches for damage
Ensure that a remote is not
transmitting continuously.
RF remote does not
work.
Units not mated
See Setting the Transmitter
(Section 6.3) and Receiver
(Section 6.4) address
procedures.
Some RF remote keys
do not work but the
ACK light blinks.
Keys were not enabled during
the setup process.
Enable keys by running the
transmitter and receiver
address procedures.
Lo Batt is blinking
Battery is low
Recharge battery
Unit turns on, then
immediately off.
Battery is low
Recharge battery
Weight will not zero
System not stable
Wait for motion light to turn
off
Increase filtering for more
stability
Zero out of range
LFT units have limited zero
range. Reduce the weight or
use tare instead
Weight will not tare or
total
System is not stable
Wait for motion light to turn
off, or if in a mechanically
noisy crane, increase the
filtering or reduce the size of
the scale increment ‘d.’ It is
also possible to increase the
motion window. Contact MSI
if you have a problem getting
the MSI-3460 to zero, tare,
or total due to stability issues.
Setpoint lights blink
Setpoint is enabled and the
trigger point has been
reached.
Disable setpoints if they are
not needed.
Manual total does not
work
A function key is not set to
“Total”
Set up Func1 or Func2 for
“Total”
Weight must be stable
Increase filtering for more
stability
Problem
Possible Cause
Solution
Figure 8-1. Troubleshooting