Rice Lake MSI-3460 Challenger 3 User Manual

Page 53

Advertising
background image

Appendix 49

Display toggles
between “Error” and
“buttn”

A key is stuck or is being held
down.

Check switches for damage
Ensure that a remote is not
transmitting continuously.

RF remote does not
work.

Units not mated

See Setting the Transmitter
(Section 6.3) and Receiver
(Section 6.4) address
procedures.

Some RF remote keys
do not work but the
ACK light blinks.

Keys were not enabled during
the setup process.

Enable keys by running the
transmitter and receiver
address procedures.

Lo Batt is blinking

Battery is low

Recharge battery

Unit turns on, then
immediately off.

Battery is low

Recharge battery

Weight will not zero

System not stable

Wait for motion light to turn
off
Increase filtering for more
stability

Zero out of range

LFT units have limited zero
range. Reduce the weight or
use tare instead

Weight will not tare or
total

System is not stable

Wait for motion light to turn
off, or if in a mechanically
noisy crane, increase the
filtering or reduce the size of
the scale increment ‘d.’ It is
also possible to increase the
motion window. Contact MSI
if you have a problem getting
the MSI-3460 to zero, tare,
or total due to stability issues.

Setpoint lights blink

Setpoint is enabled and the
trigger point has been
reached.

Disable setpoints if they are
not needed.

Manual total does not
work

A function key is not set to
“Total”

Set up Func1 or Func2 for
“Total”

Weight must be stable

Increase filtering for more
stability

Problem

Possible Cause

Solution

Figure 8-1. Troubleshooting