Vhwys 6wdqg $ywr 2ii 6wdqg, 6wruh, Auto zero maintenance setup – Rice Lake MSI-3460 Challenger 3 User Manual
Page 40
TARE
If you are already in the Cal menu
skip to step 2
1) Remove the seal screw. With
a small screwdriver press the
cal switch behind the seal
screw. The CAL setup menu
appears.
2) Press the
USER
key to
scroll to Setup.
3) Press
TARE
to enter the cal
setup menu.
4) Press
USER
to scroll to the
Auto0 menu.
5) Press
TARE
to enter the auto-
zero menu. The current setting
is displayed (blinking)
6) Change the setting between
On or OFF pressing the
USER
key.
7) Press
TARE
to set the
autozero. The display goes to
the next item in the CAL setup
menu.
8) Either press
ZERO
twice to
exit setup and store all
changes, or continue to
another setup menu item
using the
USER
Key.
&$/
Auto Zero Maintenance Setup
Cal Switch
LO BA
CAL
Remove
Hex Seal
Screw
Press Switch
behind the hole
with a small
Screwdriver
VHWYS
6WDQG
$YWR
2II
6WDQG
TARE
Next Cal Setup Menu Item
ZERO
Store and return to
weight display
&D/
ZERO
6WRUH
Calibrate Menu
USER
F
USER
F
TARE
Blinking
2Q
Blinking
CAL
USER
F
36 MSI-3460 Operator’s Manual
Figure 5-10. Auto Zero Maintenance